For laboratories that manufacture vascular stents for patient implantation, maintaining high quality standards is not optional. Producing stents is a painstaking process from the design table to the operating room, and only laboratories equipped with the right selection of quality analysis tools can create implantable stents that save patients' lives.

This becomes even more true when producing stents made from cutting-edge materials such as memory polymers, whose properties may be unfamiliar to many lab workers. Laboratories looking to get into the stent-making business need to understand the quirks of memory polymers and the best quality assessment techniques if they want downstream patients to successfully recover from disease.

Memory polymers ideal for stents
Designing and implanting stents is difficult because many of the desirable characteristics of stents are conflicting. This means that a stent designed from a single material is unlikely to have all the desirable properties, leading to poor patient outcomes. In order for patients to get the best results from a stent, they need a stent with the following features:

Formability

flexibility

The ability to create scaffolds for tissue regeneration

Durability

Detachability

Biodegradable if necessary

An additional complexity in stent design is that the stent may need to have some of these characteristics in the operating room and a different set of characteristics once the stent is implanted in the patient. For example, the stent must be moldable by the surgeon during implantation, but not so flexible that it is difficult to mold by hand.

However, once implanted in a patient, the regeneration of the patient's tissue cannot be allowed to reshape the stent-after all, a stent wouldn't be very useful if the patient's body was remodeling it during the healing process. Similarly, stents need to be able to act as a scaffold for the patient's tissue to grow so that they can heal from the implantation procedure, but not so effectively that the stent itself cannot be removed when a transplantation procedure occurs. Because of the density of new tissue growth around the stent, patients will need to have it adjusted.

Therefore, memory polymers represent a highly effective solution to the somewhat contradictory requirements of scaffolds. The memory polymer can be molded into a convenient form before implantation in the patient, and the stent will then return to the permanent shape determined prior to implantation. Then, as the patient's tissue regenerates, the scaffold can be flexible to avoid harming the patient while still providing limited scaffolding for tissue regeneration.

While memory polymers are generally not biodegradable, the fact that they do not completely overgrow with new tissue is advantageous because it means surgeons can remove memory polymer stents without causing excessive bleeding.

Common tools for quality analysis of vascular stent materials
Stents need to be maintained to the highest quality standards, whether or not they are made from memory polymer. Due to the importance of stent quality control, there are several ways to assess the quality of a stent, including:

On-site inspection microscope

Automatic stand scanning camera

Electronic energy spectrum

Importantly, these scaffold quality assurance tools can be used individually or in combination with each other. Additionally, each of these tools can be used in stands made of memory polymers or other materials, so they can be used for other laboratory tasks as well. Each tool has a specific set of advantages and disadvantages that laboratories interested in creating scaffolds need to understand.

inspect on the spot
Spot inspection using a microscope is probably the simplest method of scaffold quality analysis, as all it requires is a standard light microscope and the close attention of laboratory staff. During the on-site inspection, the scaffold was placed under a microscope and carefully examined individually on all its surfaces. Lab workers conducting spot checks look for any inclusions or anomalies in the polymer's texture to ensure it doesn't have any flaws or blemishes that could harm patients.

The great thing about spot checking is that most labs already have the infrastructure needed to start spot checking stents from the moment production begins-but they may not have enough staff time to check all stents in a reasonable amount of time. Spot checks are time-consuming, which means the low upfront price of their microscopes can be very deceiving. Additionally, spot checks are prone to human error-tired technicians may easily miss a glitch in a bracket if they've been doing quality control work for hours.

scanning camera
Automated stent scanning cameras are a relatively new addition to the field of stent quality analysis. In short, automated stent scanning cameras utilize a mechanical stage, optical microscope, and camera rig to take hundreds of photos of every angle of the stent. The process is then repeated as the stent changes shape. A computer program then analyzes the photos to evaluate whether the scaffold has any blemishes or defects that could be harmful to the patient and notifies lab staff of the results.

Bracket scanning cameras are very expensive, but they overcome most of the problems with spot inspection methods through automation. While stand scan cameras are not necessarily perfect, over a long period of time they are likely to miss fewer issues than humans doing spot checks. Stand scanning cameras also free up personnel to perform other tasks, which is invaluable in a small laboratory.

Electronic energy spectrum
Electron spectroscopy is the best choice for quality analysis of memory polymer scaffolds. In electron spectroscopy, lab workers examine the surface of the scaffold as it appears on a microscopic scale. Observing the stent surface at a microscopic scale immediately exposes any impurities in the stent material and also alerts workers to microstructural issues with the stent. Therefore, electron spectroscopy is by far the most comprehensive method for analyzing stents, even though it does not necessarily offer any special advantages when examining memory polymer stents compared with stents made of conventional materials.

The huge disadvantage of electron spectroscopy is that it is very expensive and extremely slow. Electronic spectroscopy requires a lot of hands-on operator time, not to mention extensive maintenance and training. What's more, electronic spectroscopy doesn't necessarily expose the most obvious flaws of memory polymer stents, such as jagged edges that could harm patients. Because the images generated by electron spectroscopy are designed to analyze microscopic phenomena, macroscopic phenomena like jagged stent edges would be too large to see.

Achieving stent quality successfully
Laboratories seeking to produce memory polymer scaffolds will find that they obtain the best results when they use a combination of different quality analysis methods. By combining automated analysis with occasional spot checks and analysis of odd spectra, laboratories can gain a comprehensive understanding of how their scaffolds are affected by the manufacturing process. Likewise, by working with an experienced supplier who understands the needs of the stent manufacturing team, laboratories will ensure they never have to hunt for necessary supplies.