Home > Knowledge > Content

Ultra-low temperature refrigerator storage temperature

Apr 16, 2024

The storage temperature of ultra-low temperature refrigerators is usually between -40°C and -196°C. Different models of ultra-low temperature refrigerators may have different storage temperature ranges. According to different storage needs, the temperature of the ultra-low temperature refrigerator can be adjusted to meet different storage requirements.

The storage temperature range of common ultra-low temperature refrigerators is as follows:

-40℃ to -86℃: Usually used to store biological samples, cells, viruses, bacteria, etc.

-86℃ to -150℃: usually used to store cells, enzymes, antigens, antibodies, serum, deoxyribonucleic acid (DNA), ribonucleic acid (RNA), etc.

-150℃ to -196℃: Usually used to store biological samples, cells, viruses, bacteria, etc.

It should be noted that the lower the storage temperature of the ultra-low temperature refrigerator, the better the protection of the stored biological materials, but at the same time, care must be taken to prevent freezing damage to the samples. Therefore, during storage, the storage temperature needs to be adjusted and controlled according to different biological substances and requirements.

When storing biological samples and other biological materials in ultra-low temperature refrigerators, in order to prevent freezing damage to the samples, some measures need to be taken, as follows:

Control the cooling rate: Before placing the sample in the ultra-low temperature refrigerator, it should be cooled to below room temperature. This can effectively avoid freezing damage to the sample during the cooling process. When placing samples in an ultra-low temperature refrigerator, the cooling rate should be controlled to avoid cooling too quickly.

Gradual cooling: In order to prevent freezing damage to the sample during the cooling process, a gradual cooling method can be used. The specific method is to gradually lower the temperature after placing the sample in an ultra-low temperature refrigerator, for example, by 2-3°C every day until the target temperature is reached.

Use cryoprotectants: Some biological substances are prone to freezing damage during freezing. In order to avoid this, cryoprotectants, such as glycerol, ethylene glycol, glucose, etc., can be added to the samples to lower the freezing point of the samples and protect them. Cellular or molecular structures are not destroyed.

Control humidity: In ultra-low temperature refrigerators, too high humidity may cause frost to form on the surface of the sample, causing freezing damage. Therefore, it is necessary to control the humidity in the cold room and maintain a low humidity level.

Regular inspections: Ultra-low temperature refrigerators should be inspected regularly to ensure that the temperature, humidity and other parameters inside the freezer meet the requirements to avoid freezing damage to samples due to the equipment itself.

Send Inquiry